Current: Input Charge
(Solar charge current) : Maximum 10 Ampere (Max. module wattage 120 Wp)
Current Rating : Output Maximum 10 Ampere
Over load : 11 Ampere
Battery Voltage : Nominal Automatic recognition: 12/24VDC
PV Voltage : Nominal Automatic recognition:12/24VDC
PV Open Circuit Voltage : Maximum 21/42VDC wattage
Standby Power Consumption (no load) : Less than 5mA
Charge Algorithm : 2-stage charge PWM
Voltage Boost : 14.5/29 V DC
Voltage Equalization : 14.8/29.6 V DC
Voltage Float : 13.7/27.4 V DC
LVD : 11.0/22.0 V DC
LVR : 12.2/22.4 V DC
HVD : 14.8/29.6 V DC
USB Charger (maximum current limit) : 0.5 Ampere (max.)
Dusk to Dawn mode : Selectable by switch
DUSK TO DAWN: Switch is kept ON then dusk to dawn mode is selected. With this mode turned ON Load is connected when sunlight is not present and the load is turned OFF when solar is present.
Normal Mode: Switch is kept OFF then Normal mode is selected.
Protection
Deep Discharge : The load is automatically cut off from the battery once the battery voltage reaches LVD. This is done to protect t the battery from deep discharge.
Overload Protection : The charge controller has electronic overload protection, once the charge controller load is on the threshold of maximum limit top LED glows and signals to reduce load, or else this protection automatically disconnects the load after a certain time delay.
Short Circuit protection : If the Load terminal is short-circuited the electronic protection automatically disconnects the load instantly.
Battery circuit polarity : The electronic circuit has protection for reverse polarity.
SPV Module reverse connection : The electronic protection will prevent any current from SPV Modules & respective LED indications will not glow.
Dimension : 130x125x40(all in mm)
Protection class : IP20
Weight : 200gm (Max)
Connecting the Charge Controller
1. Mount the charge controller on a dry indoor surface using 4 mounting holes.
2. Connect wires for battery to the terminals marked BATT (+) & BATT (-). Connect the wires to Controller & then to battery. Make sure the Terminals are connected.
3. Connect wires for Solar Modules to the terminals marked LOAD (+) & LOAD (-).
WARRANTY
THE Charge controller is warranted for 1 year against manufacturing defects or bad workmanship from the date of purchase:
The Warranty will be void if the unit is:
a) Not used according to the manual
b) Modified or the warranty seal has been tampered with
c) Warranty card is not produced incomplete
d) Used improperly or abused
e) Serviced by an unauthorized person or center